Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Ultrasound ; 26(4): 879-889, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37783892

RESUMO

PURPOSE: Muscular atrophy implies structural and functional alterations related to muscular force production and movement. This condition has been reported to be the main reason for generalized muscle weakness; it reflects the severity of the disease and can have a profound impact on short- and long-term clinical outcomes. The purpose of this study was to determine whether muscle atrophy ultrasound parameters early predict muscle weakness, morbidity, or 28-days mortality. METHODS: This was a prospective, observational single center cohort study. Ultrasound was used to determine the cross-sectional area and muscle thickness of the rectus femoris on the first and third day of ICU stay. The main outcome was the incidence of significant muscle atrophy (≥ 10%). RESULTS: Ultrasound measurements were made in 31 patients, 58% (18/31) of which showed significant muscle atrophy. The relative loss of muscle mass per day was 1.78 at 5% per day. The presence of muscle atrophy presents increased risk for limb muscle weakness and handgrip weakness. The 28-days mortality rate was similar in both subgroups. CONCLUSION: The presence of muscle atrophy presents an increased clinical risk for the development of limb ICUAW and handgrip, although these observations were not statistically significant. The results could be used to plan future studies on this topic.


Assuntos
Estado Terminal , Força da Mão , Humanos , Estudos Prospectivos , Estudos de Coortes , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/etiologia , Debilidade Muscular/diagnóstico por imagem , Debilidade Muscular/complicações , Músculo Quadríceps/diagnóstico por imagem , Unidades de Terapia Intensiva
2.
Ultrasound J ; 15(1): 14, 2023 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-36934375

RESUMO

BACKGROUND: The assessment of gastric content and volume using bedside ultrasound (US) has become a useful tool in emergency departments, anesthesiology departments and inpatient wards, as it provides a rapid and dynamic assessment of the gastric content of patients, which, allows making decisions regarding the risk of regurgitation or the need to adjust the strategy used to induce general anesthesia in patients with a full stomach. This assessment consists of two evaluations: a qualitative one, in which the status of the antrum, in terms of gastric content, is classified into three categories (empty, liquid content and full), and a quantitative one, where gastric volume is estimated. The objective of this study was to estimate the intra-observer and inter-observer agreement in ultrasound assessment of gastric content and volume in critically ill patients receiving enteral nutrition. RESULTS: A total of 41 patients were included and each examiner performed 64 gastric US (n = 128). Participants' average age was 56.5 years (SD ± 12.6) and 63.4% were men. Regarding the qualitative evaluation of the antrum, in supine position both examiners classified the gastric content as grade 0 in 1 gastric US (1.5%), grade 1 in 4 gastric US (6.2%) and grade 2 in 59 (92.1%). Regarding intra-observer variability in the measurement of the area of the antrum, Lin's concordance correlation coefficient (CCC), the difference of means between measurements and the 95% limits of agreement of Bland and Altman values were 0.95 (95% CI 0.940-0.977), - 0.47 cm2 (SD ± 1.64) and - 3.70 cm2 to 2.75 cm2, respectively, in EC1, and 0.94 (95% CI 0.922-0.973), - 0.18 cm2 (SD ± 2.18) and - 4.47 cm2 to 4.09 cm2 in EC2. Concerning to inter-observer variability (EC1 vs EC2) in the measurement of the area of the antrum and of gastric volume, the following CCC, mean difference between measurements and 95% limits of agreement of Bland and Altman values were obtained: measurement of the area of the antrum: 0.84 (95% CI 0.778-0.911), - 0.86 cm2 (SD ± 3.38) and - 7.50 cm2 to 5.78 cm2; gastric volume measurement: 0.84 (95% CI 0.782-0.913), - 12.3 mL (SD ± 49.2) and - 108.8 mL to 84.0 mL. CONCLUSIONS: The assessment of gastric content and volume using bedside US in critically ill patients on mechanical ventilation and receiving enteral nutrition showed a good intra and inter-rater reliability. Most of the patients included in the study had a high risk of pulmonary aspiration, since, according to the results of the gastric US evaluation, they had gastric volumes > 1.5 mL/kg.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA